Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiat Prot Dosimetry ; 197(3-4): 135-145, 2021 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-34875692

RESUMO

We assessed variations in chest CT usage, radiation dose and image quality in COVID-19 pneumonia. Our study included all chest CT exams performed in 533 patients from 6 healthcare sites from Brazil. We recorded patients' age, gender and body weight and the information number of CT exams per patient, scan parameters and radiation doses (volume CT dose index-CTDIvol and dose length product-DLP). Six radiologists assessed all chest CT exams for the type of pulmonary findings and classified CT appearance of COVID-19 pneumonia as typical, indeterminate, atypical or negative. In addition, each CT was assessed for diagnostic quality (optimal or suboptimal) and presence of artefacts. Artefacts were frequent (367/841), often related to respiratory motion (344/367 chest CT exams with artefacts) and resulted in suboptimal evaluation in mid-to-lower lungs (176/344) or the entire lung (31/344). There were substantial differences in CT usage, patient weight, CTDIvol and DLP across the participating sites.


Assuntos
COVID-19 , Brasil , Humanos , Doses de Radiação , SARS-CoV-2 , Tomografia Computadorizada por Raios X
2.
Radiol. bras ; 43(6): 355-361, nov.-dez. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-571673

RESUMO

OBJETIVO: Avaliar a concordância entre o ultrassom Doppler e a ressonância magnética e a reprodutibilidade interobservador desses métodos na quantificação do volume de fluxo portal em indivíduos esquistossomóticos. MATERIAIS E MÉTODOS: Foi realizado estudo transversal, observacional e autopareado, avaliando 21 pacientes portadores de esquistossomose hepatoesplênica submetidos a mensuração do fluxo portal por meio de ressonância magnética (utilizando-se a técnica phase-contrast) e ultrassom Doppler. RESULTADOS: Observou-se baixa concordância entre os métodos (coeficiente de correlação intraclasse: 34,5 por cento [IC 95 por cento]). A reprodutibilidade interobservador na avaliação pela ressonância magnética (coeficiente de correlação intraclasse: 99,2 por cento [IC 95 por cento] / coeficiente de correlação de Pearson: 99,2 por cento / média do fluxo portal = 0,806) e pelo ultrassom Doppler (coeficiente de correlação intraclasse: 80,6 por cento a 93,0 por cento [IC 95 por cento] / coeficiente de correlação de Pearson: 81,6 por cento a 92,7 por cento / média do fluxo portal = 0,954, 0,758 e 0,749) foi excelente. CONCLUSÃO: Há uma baixa concordância entre o ultrassom Doppler e a ressonância magnética na mensuração do volume de fluxo na veia porta. A ressonância magnética e o ultrassom Doppler são métodos reprodutíveis na quantificação do fluxo portal em pacientes portadores de hipertensão porta de origem esquistossomótica, apresentando boa concordância interobservador.


OBJECTIVE: To evaluate the agreement between Doppler ultrasonography and magnetic resonance imaging as well as the interobserver reproducibility of both methods in the measurement of portal blood flow in schistosomal patients. MATERIALS AND METHODS: A cross-sectional, observational, self-paired study evaluated 21 patients with schistosomiasis mansoni submitted to measurement of portal blood flow with phase-contrast magnetic resonance imaging and Doppler ultrasonography. RESULTS: A poor intermethod agreement was observed (intraclass correlation coefficient: 34.5 percent [CI 95 percent]). On the other hand, the interobserver reproducibility was excellent in the evaluation by magnetic resonance imaging (intraclass correlation coefficient: 99.2 percent [CI 95 percent] / Pearson's correlation coefficient: 99.2 percent / portal blood flow = 0.806) and by Doppler ultrasonography (intraclass correlation coefficient: 80.6 to 93.0 percent [CI 95 percent] / Pearson's correlation coefficient: 81.6 percent to 92.7 percent / portal blood flow = 0.954, 0.758 and 0.749). CONCLUSION: There is a poor intermethod agreement in the measurement of portal blood flow. Nevertheless, contrast-phase magnetic resonance imaging and Doppler ultrasonography demonstrated to be reproducible methods presenting excellent interobserver agreement in the quantification of portal blood flow in patients with hepatosplenic schistosomiasis-related portal hypertension.


Assuntos
Hipertensão Portal , Hipertensão Portal , Veia Porta/fisiologia , Imageamento por Ressonância Magnética , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Esquistossomose , Ultrassonografia Doppler
3.
Mem Inst Oswaldo Cruz ; 105(4): 409-13, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20721483

RESUMO

The aim of this study was to assess interobserver agreement of ultrasound parameters for portal hypertension in hepatosplenic mansonic schistosomiasis. Spleen size, diameter of the portal, splenic and superior mesenteric veins and presence of thrombosis and cavernous transformation were determined by three radiologists in blinded and independent fashion in 30 patients. Interobserver agreement was measured by the kappa index and intraclass correlation coefficient. Interobserver agreement was considered substantial (kappa = 0.714-0.795) for portal vein thrombosis and perfect (kappa = 1) for cavernous transformation. Interobserver agreement measured by the intraclass correlation coefficient was excellent for longitudinal diameter of the spleen (r = 0.828-0.869) and splenic index (r = 0.816-0.905) and varied from fair to almost perfect for diameter of the portal (r = 0.622-0.675), splenic (r = 0.573-0.913) and superior mesenteric (r = 0.525-0.607) veins. According to the results, ultrasound is a highly reproducible method for the main morphological parameters of portal hypertension in schistosomiasis patients.


Assuntos
Hipertensão Portal/diagnóstico por imagem , Hepatopatias Parasitárias/diagnóstico por imagem , Sistema Porta/ultraestrutura , Esquistossomose mansoni/diagnóstico por imagem , Esplenopatias/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Hipertensão Portal/etiologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tamanho do Órgão , Sistema Porta/parasitologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Esquistossomose mansoni/complicações , Esplenopatias/parasitologia , Ultrassonografia Doppler em Cores , Trombose Venosa/parasitologia
4.
Mem. Inst. Oswaldo Cruz ; 105(4): 409-413, July 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-554805

RESUMO

The aim of this study was to assess interobserver agreement of ultrasound parameters for portal hypertension in hepatosplenic mansonic schistosomiasis. Spleen size, diameter of the portal, splenic and superior mesenteric veins and presence of thrombosis and cavernous transformation were determined by three radiologists in blinded and independent fashion in 30 patients. Interobserver agreement was measured by the kappa index and intraclass correlation coefficient. Interobserver agreement was considered substantial (ê = 0.714-0.795) for portal vein thrombosis and perfect (ê = 1) for cavernous transformation. Interobserver agreement measured by the intraclass correlation coefficient was excellent for longitudinal diameter of the spleen (r = 0.828-0.869) and splenic index (r = 0.816-0.905) and varied from fair to almost perfect for diameter of the portal (r = 0.622-0.675), splenic (r = 0.573-0.913) and superior mesenteric (r = 0.525-0.607) veins. According to the results, ultrasound is a highly reproducible method for the main morphological parameters of portal hypertension in schistosomiasis patients.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Portal , Hepatopatias Parasitárias , Sistema Porta/ultraestrutura , Esquistossomose mansoni , Esplenopatias , Trombose Venosa , Estudos Transversais , Hipertensão Portal , Variações Dependentes do Observador , Tamanho do Órgão , Estudos Prospectivos , Sistema Porta , Reprodutibilidade dos Testes , Esquistossomose mansoni , Esplenopatias , Ultrassonografia Doppler em Cores , Trombose Venosa
5.
Radiol. bras ; 42(5): 277-282, set.-out. 2009. ilus, tab
Artigo em Português | LILACS | ID: lil-530173

RESUMO

OBJETIVO: Descrever as alterações das vias biliares pela colangiografia por ressonância magnética (CPRM) na esquistossomose hepatoesplênica e avaliar a concordância interobservador da CPRM na detecção de colangiopatia esquistossomótica. MATERIAIS E MÉTODOS: Estudo prospectivo e transversal em 24 pacientes com a forma hepatoesplênica da esquistossomose mansoni e em 6 pacientes sadios, como grupo controle, com avaliação da via biliar pela CPRM. As alterações da via biliar consideradas foram: distorção, afilamento, estenose, dilatação e irregularidade. Foi calculada a concordância interobsevador para alteração da via biliar com o teste de McNemar e o índice kappa (κ). RESULTADOS: A concordância interobservador na caracterização de distorção e afilamento da via biliar foi quase perfeita (κ = 0,867; intervalo de confiança [IC] 95 por cento [0,512-1,0] e κ = 0,865; IC 95 por cento [0,51-1,0], respectivamente). A concordância foi substancial para a estenose (κ = 0,78; IC 95 por cento [0,424-1,0]), moderada para dilatação (κ = 0,595; IC 95 por cento [0,247-0,942]) e regular para afilamento (κ = 0,229; IC 95 por cento [0,095-0,552]). CONCLUSÃO: As alterações observadas nas vias biliares foram, em ordem decrescente de ocorrência: distorção, afilamento, estenose, dilatação e irregularidade. A concordância interobservador para sinais de colangiopatia esquistossomótica foi quase perfeita para distorção e afilamento e substancial para estenose.


OBJECTIVE: To describe changes of the biliary tree demonstrated by magnetic resonance cholangiography (MRC) in patients with the hepatosplenic presentation of schistosomiasis mansoni, and evaluating the interobserver agreement in the detection of schistosomal cholangiopathy. MATERIALS AND METHODS: Prospective, cross-sectional study involving 24 patients with hepatosplenic schistosomiasis and 6 healthy patients (control group) submitted to biliary tree evaluation by MRC. The following changes of the biliary tree were considered: distortion, thinning, stenosis, dilation and irregularity. The interobserver agreement in the detection of biliary tree changes was calculated with the McNemar's test and the kappa index of agreement (κ). RESULTS: The interobserver agreement in the detection of distortion and thinning of the biliary tree was almost perfect (κ = 0.867; confidence interval [CI] 95 percent [0.512-1.0] and κ = 0.865; CI 95 percent [0.51-1.0], respectively). There was a substantial agreement for stenosis (κ = 0.78; CI 95 percent [0.424-1.0]), moderate agreement for dilation (κ = 0.595; CI 95 percent [0.247-0.942]) and mild agreement for thinning (κ = 0.229; CI 95 percent [0.095-0.552]). CONCLUSION: In a decreasing order of frequency, the changes of the biliary tree were observed: distortion, thinning, stenosis, dilation and irregularity. The interobserver agreement for signs of schistosomal cholangiopathy was almost perfect for distortion and thinning, and substantial for stenosis.


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Pessoa de Meia-Idade , Ductos Biliares/anormalidades , Esquistossomose mansoni/diagnóstico , Esquistossomose mansoni/patologia , Schistosoma/parasitologia
6.
Radiol. bras ; 41(6): 367-372, nov.-dez. 2008. ilus, tab
Artigo em Português | LILACS | ID: lil-507116

RESUMO

OBJETIVO: Comparar a ressonância de baixo campo (0,2 T) com a de alto campo (1,5 T) na avaliação daendometriose pélvica e adenomiose. MATERIAIS E MÉTODOS: Foram estudadas, prospectivamente, 27 pacientes do sexo feminino com suspeita clínica de endometriose, realizando-se exames de ressonância magnética de alto campo e baixo campo. Um mesmo radiologista realizou a leitura dos exames, iniciando pelo baixo campo, seguido pelo alto campo, usando como padrão-ouro o alto campo. RESULTADOS: Das 27 pacientes estudadas, 18 (66,7%) apresentaram alguma lesão indicativa de endometriose nos exames realizados no alto campo. Foram corretamente diagnosticados pelo baixo campo 14 destas pacientes. Endometriomas, lesões tubárias e focos de endometriose maiores do que 7 mm identificados pelo alto campo foramtambém identificados no baixo campo, com acurácia, sensibilidade e especificidade de 100%. Das novepacientes com adenomiose caracterizadas pelo alto campo, oito foram corretamente identificadas pelo baixo campo, com acurácia, sensibilidade e especificidade de 88,9%. CONCLUSÃO: A ressonância de baixo campo apresentou baixa sensibilidade na detecção de pequenos focos de endometriose, alta sensibilidade na detecção de endometriomas e focos de endometriose grandes, e boa acurácia na detecção da adenomiose quando comparada com a ressonância de alto campo.


Assuntos
Humanos , Feminino , Adolescente , Adulto , Endometriose/diagnóstico , Imageamento por Ressonância Magnética , Brasil , Estudos Observacionais como Assunto , Demografia , Estudos Prospectivos
7.
Radiol. bras ; 41(2): 69-73, mar.-abr. 2008. ilus
Artigo em Português | LILACS | ID: lil-482990

RESUMO

OBJETIVO: Medir a sensibilidade e a reprodutibilidade da ultra-sonografia na detecção de nódulos sideróticos esplênicos em pacientes esquistossomóticos, tendo a ressonância magnética como padrão de referência. MATERIAIS E MÉTODOS: Na primeira fase do trabalho, 21 pacientes portadores de esquistossomose na forma hepatoesplênica com diagnóstico de nódulos sideróticos à ressonância magnética foram submetidos a avaliação ultra-sonográfica para a determinação da sensibilidade do método. Na segunda fase, com o objetivo de avaliar a reprodutibilidade da ultra-sonografia na detecção e na quantificação de nódulos sideróticos (A: 1-5 nódulos; B: 6-20 nódulos; C: mais de 20 nódulos), outros 30 pacientes esquistossomóticos foram submetidos a avaliação ultra-sonográfica de forma cega e independente por dois observadores. A reprodutibilidade foi medida por meio da concordância entre os observadores e do teste kappa. RESULTADOS: A sensibilidade da ultra-sonografia foi de 95,2 por cento (intervalo de confiança a 95 por cento [77,3 por cento; 99,2 por cento]). A concordância entre ultra-sonografia e ressonância magnética para a detecção de nódulos sideróticos foi de 96,7 por cento (intervalo de confiança a 95 por cento [82,8 por cento; 99,9 por cento]). Para a classificação dos nódulos conforme a sua quantificação, o índice kappa demonstrou concordância interobservador substancial (kappa = 0,67). CONCLUSÃO: A ultra-sonografia é um método que apresenta elevada sensibilidade e boa precisão para a avaliação de nódulos sideróticos esplênicos.


OBJECTIVE: To evaluate ultrasound sensitivity and reproducibility as compared with magnetic resonance imaging as the gold standard in the detection of splenic siderotic nodules in schistosomal patients. MATERIALS AND METHODS: Initially, 21 patients with hepatosplenic schistosomiasis and diagnosed with splenic siderotic nodules by magnetic resonance imaging were ultrasonographically evaluated for determining the method sensitivity. In a second phase, the method reproducibility in the detection and quantification of siderotic nodules (A: 1-5 nodules; B: 6-20 nodules; C: > 20 nodules) was evaluated in 30 patients who were submitted to ultrasonography blindly and independently assessed by two observers. Interobserver agreement was measured by kappa statistics. RESULTS: Ultrasound sensitivity was 95.2 percent (95 percent confidence interval [77.3 percent; 99.2 percent]). Intermethod agreement in the detection of siderotic nodules was 96.7 percent (95 percent confidence interval [82.8 percent; 99.9 percent]). For classification of nodules according to their quantification, the kappa test demonstrated a statistically significant interobserver agreement (kappa = 0.67). CONCLUSION: Ultrasonography is highly sensitive and accurate in the assessment of splenic siderotic nodules in schistosomal patients.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Baço/fisiopatologia , Baço , Esquistossomose/complicações , Hipertensão Portal , Hepatopatias , Hipertensão Portal/etiologia , Esquistossomose , Espectroscopia de Ressonância Magnética , Hemossiderina
8.
Radiol. bras ; 40(6): 377-381, nov.-dez. 2007. ilus, tab
Artigo em Português | LILACS | ID: lil-471996

RESUMO

OBJETIVO: Medir a concordância intra- e interobservador da classificação ultra-sonográfica qualitativa para graduar a fibrose periportal adotada no encontro de Niamey em 1996. MATERIAIS E MÉTODOS: No período de fevereiro de 2005 a março de 2006 foi realizado estudo prospectivo, observacional e transversal em 30 pacientes esquistossomóticos, sem outras hepatopatias associadas, submetidos a ultra-sonografia abdominal e classificados segundo os critérios de Niamey. Os exames foram realizados por dois radiologistas de forma independente em diferentes momentos: durante o exame dinâmico (primeiro momento) e 30 e 90 dias depois (segundo e terceiro momentos) do exame, por meio da documentação fotográfica analisada em estação de trabalho. A concordância intra- e interobservador foi avaliada pelo teste kappa. RESULTADOS: A concordância intra-observador medida pelo teste kappa foi 0,43 para o observador 1 e 0,57 para o observador 2. A concordância interobservador durante o estudo dinâmico e na avaliação fotográfica foi, respectivamente, de 0,46 e 0,71. CONCLUSÃO: O uso do ultra-som para classificar a fibrose periportal segundo o protocolo de Niamey apresentou uma reprodutibilidade que variou de moderada a substancial.


OBJECTIVE: To determine the intra- and interobserver agreement in the classification of periportal fibrosis, according to the criteria defined at the Niamey Workshop of 1996. MATERIALS AND METHODS: A prospective, observational and transverse study was developed in the period between February, 2005 and March, 2006, in 30 schistosomal patients with no other hepatic findings associated, submitted to abdominal ultrasound. Ultrasonographic studies were independently performed and reviewed by two radiologists at three different moments: the dynamic examination itself (first moment), 30 and 90 days later (second and third moments), by means of the images review performed in a workstation. Intra- and interobserver agreement was evaluated by means of the kappa test. RESULTS: Intraobserver agreement was 0.43 for the first, and 0.57 for the second observer. Interobserver agreement as regards the dynamic examination and images review was respectively 0.46 and 0.71. CONCLUSION: Ultrasonography demonstrated moderate to substantial reproducibility in the classification of periportal fibrosis according to the Niamey criteria.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Esquistossomose mansoni/epidemiologia , Esquistossomose mansoni/patologia , Esquistossomose mansoni , Reprodutibilidade dos Testes , Esquistossomose mansoni , Brasil , Estudos Transversais , Fibrose , Estudos Observacionais como Assunto , Estudos Prospectivos
9.
Radiol. bras ; 40(5): 303-308, set.-out. 2007. ilus, tab
Artigo em Inglês, Português | LILACS | ID: lil-467764

RESUMO

OBJETIVO: Avaliar a reprodutibilidade da ressonância magnética e a concordância entre a ultra-sonografia e a ressonância magnética na classificação da fibrose periportal em pacientes esquistossomóticos, segundo os critérios qualitativos de Niamey. MATERIAIS E MÉTODOS: Foi realizado estudo prospectivo e duplo-cego, entre fevereiro de 2005 e junho de 2006, em 20 pacientes (10 homens e 10 mulheres, idades entre 24 e 60 anos, média de 42,75 anos) com diagnóstico de esquistossomose mansônica. As imagens de ultra-sonografia e de ressonância magnética foram avaliadas por dois examinadores experientes de forma independente. Foi medida a concordância interobservador para a ressonância magnética e entre a ressonância magnética e a ultra-sonografia. RESULTADOS: A ressonância magnética apresentou resultados concordantes entre os observadores em 14 pacientes (70 por cento). Quando comparamos a ressonância magnética com a ultra-sonografia, obtivemos concordância em apenas seis pacientes pelo observador 1 (30 por cento) e em oito pacientes pelo observador 2 (40 por cento). CONCLUSÃO: A ressonância magnética tem boa reprodutibilidade na avaliação de fibrose periportal em pacientes com esquistossomose avançada, porém sua concordância com a ultra-sonografia é fraca.


OBJECTIVE: To evaluate the reproducibility of magnetic resonance imaging and the agreement between ultrasound and magnetic resonance imaging in the classification of periportal fibrosis in patients with schistosomiasis based on Niamey's qualitative criteria. MATERIALS AND METHODS: A prospective, double-blinded study was conducted between February 2005 and June 2006 with 20 patients (10 men and 10 women, with ages ranging between 24 and 60 years, mean age 42.7 years) diagnosed with schistosomiasis mansoni. Both ultrasound and magnetic resonance images were independently evaluated by two experienced observers. Interobserver agreement was evaluated for findings of periportal fibrosis on magnetic resonance images and in a comparison between magnetic resonance and ultrasound images. RESULTS: The analysis of magnetic resonance images showed total interobserver agreement in 14 patients (70 percent). The comparison between ultrasound and magnetic resonance imaging showed agreement between images in only six cases (30 percent) by observer 1, and in eight cases (40 percent) by observer 2. CONCLUSION: Magnetic resonance imaging presents a good reproducibility in the evaluation of periportal fibrosis in later stages of schistosomiasis, however, the correlation between magnetic resonance imaging and ultrasound is poor.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Diagnóstico por Imagem , Esquistossomose mansoni/diagnóstico , Esquistossomose mansoni/patologia , Esquistossomose/diagnóstico , Fibrose/classificação , Imageamento por Ressonância Magnética , Veia Porta/ultraestrutura , Diagnóstico Diferencial , Fibrose , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia , Veia Porta/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...